Page 7 - GarlockFluidSealing2010

SEO Version

A-5
Nuclear Applications
Style G-700
Highest standards
¦
When used as end rings together with high purity
GRAPH-LOCK
®
rings, G700 is ideal for critical
valve applications** in nuclear and power genera-
tion industries
¦
Tested by independent laboratories; compliant with:
• MIL-P-24583B (SH)
• General Electric Spec. D50YP12 Rev. 2
¦
Contains no PTFE or other lubricants
¦
Non-abrasive; very low coeffcient of friction
¦
Will not fray
Specifcations
Construction:
Highest grade graphite flament with
an exclusive graphite dispersion,
in LATTICE BRAID
®
construction
Temperature:
-328°F (-200°C) to +1200°F
(+650°C) in steam; +1625°F
(+900°C) in free oxygen-exclusive
environments such as nitrogen and
carbon dioxide; +850°F (+455°C)
atmosphere
pH range:
0-14 (except strong oxidizers)
Pressure:
To 4,000 psi (275 bar) plus, when
used with GRAPH-LOCK
®
center
rings
* INCONEL
®
is a registered trademark of Inco Alloys International, Inc.
** Used as end rings ONLY.
WARNING:
Properties/applications shown throughout this brochure are typical. Your specifc applica-
tion should not be undertaken without independent study and evaluation for suitability.
For specifc application recommendations consult Garlock. Failure to select the proper
sealing products could result in property damage and/or serious personal injury.
Performance data published in this brochure has been developed from feld testing,
customer feld reports and/or in-house testing.
While the utmost care has been used in compiling this brochure, we assume no respon-
sibility for errors. Specifcations subject to change without notice. This edition cancels
all previous issues. Subject to change without notice.
GARLOCK is a registered trademark for packings, seals, gaskets, and other products
of Garlock.