Page 3 - PF Parker Outside

SEO Version

SensoControl Serviceman Diagnostic Meter
Function Descriptions
Serviceman Technical
Data
1 Two Line Measurement Display
2 RESET
resets mini
mum and maxi
mum values to zero
3 ON/OFF
Switch
4
MAX
displays maxi
mum value since meter was last reset or turned on
5 INP1/2
selects whether meter will display measurement from
Input 1 or Input 2
6 l1-l2
displays the differential value of Input 1 minus Input 2
7
MIN
displays mini
mum value since meter was last reset or turned on
8 PRINT
sends displayed measurements to PC or printer
9 HOLD
resets display to zero
10 Two Inputs
(5 pin)
11 External
Power Supply Socket
12 Data Output
via RS232 interface to transmit measured values to PC
ON/OFF
RESET
MAX
MIN
ZERO
INP1/2
1-2
PRINT
INP1 PSI
INP2 GPM
Serviceman
SCM-152
INPT1
INPT2
10
9
8
7
6
5
4
3
2
1
11
12
Meter
• 2 Line Display Shows Both Inputs
• 4 Digit LCD Text Display
• Display of Pressure, Temperature,
Flow and Rotational
Speed
- Pressure in PSI and Bar
- Temperature in °F and °C
- Flow in GPM and l/min.
- Rotational
Speed in RPM
Housing
• ABS Plastic Housing
• Protective Rubber Cover
• Carrying Strap
• Integral
Stand
Inputs
• Two 5-pin push-pull Inputs
• 0-3 Volts (R=470 k )
• 12 Bit A/D Converter
• Automatic Sensor Recognition
• 2 ms Scanning Rate
Ambient Conditions
• Operating Temperatures
32°F to 122°F (0°C to 50°C)
• Storage Temperatures
-4°F to 140°F (-20°C to 60°C)
Output
• RS232 Interface to transfer
measured values to a PC.
The SCSW-KIT-152 software and
adapter kit is required for data
transfer to a PC.
Power Requirements
• 9 Volt Rechargeable Ni-MH Battery
• Recharge circuit for use with
external power supply.
• 5 Hour Battery Life
Special
Note
All
Parker SensoControl hand-held
diagnostic meters are now equipped
with the same 5-pin push-pull
style connector ports.
This means accessories such as
pressure sensors, temperature sensors,
flow meters, tachometers and cables are
all interchangeable between Serviceman
and Service Master meters.