Page 476 - 4300 Catalog Cover.pdf

SEO Version

U24
Parker Hannifin Corporation
Tube Fittings Division
Columbus, Ohio
4300 Catalog
General Technical
Dimensions and pressures for reference only, subject to change.
Fitting and Adapter Pressure
Ratings
Pressure Ratings
Pressure ratings shown on the product pages of this catalog are
for dynamic systems.Avastmajorityof systemswhereour fittings
are used fall in this category. However, there are applications,
suchas hydraulic jacks, where the systempressure is essentially
static once it is pressurized. For this type of an application the
fittings can be used at higher pressures.
The dynamic and static systems can be defined as follows:
Dynamic:
Asystem inwhich theoperatingpressurefluctuates, in
accordance with load, up to a maximum pressure limited by the
relief valve. In addition, the systemmay also experience shocks,
vibration and temperature excursions. Example: A backhoe.
Static:
A system, once pressurized, is essentially free of pres-
sure fluctuations, shock, vibration and temperature excursions,
with such pressurizations not exceeding 30,000 in the life of the
system. Example: A hydraulic jack.
The dynamic pressure ratings are based on a minimum design
factor of 4. In other words, the fitting is capable of holding a
pressure equal to 4 times the rated pressure before leakage
or failure. For static applications, the design factor can be 3.
Hence, the static rating can be determined by multiplying the
dynamic rating by 1.33.
Static pressure rating = 1.33 x Dynamic pressure rating
Example: Static pressure rating for a fitting rated at 6000 psi =
1.33 x 6000 = 8000 psi
Higher (dynamic) Ratings
Some parts are capable of performing at higher pressures than
those shown on the product pages. For information on higher
rating