Page 7 - ParkerMULTITUBE

SEO Version

Parker Hannifn Corporation
Parfex Division
Ravenna, OH
Chemical Processing and Refneries
Catalog Number 4200-M-2
Part
Number
Tubing
Insulation**
Thickness
(in.)
Jacket
Thickness
(in.)
Nominal
Product
O.D.
(in.)
Minimum
Bendng
Radius
(in)
Maximum
Pulling
Tension
(lbs.)
Product
Weight
(lbs./
100ft.)
Horizontal/
Vertical
Support
Centers (ft.)
Size (in.)
Material
O.D. Wall
TT-10430 Copper
1/4 0.030 0.20
.08
.81
8
150
21.6
5
TT-10632 Copper
3/8 0.032 0.24
.08
1.01
10
250
31.7
6
TT-10835 Copper
1/2 0.035 0.24
.08
1.14
12
350
40.8
8
TT-10649 Copper
3/8 0.049 0.24
.08
1.01
10
250
37.8
6
TT-10849 Copper
1/2 0.049 0.24
.08
1.14
12
350
47.9
8
TT-20435 Welded
Stainless Steel
1/4 0.035 0.20
.08
.81
8
250
21.7
6
TT-20635 Welded
Stainless Steel
3/8 0.035 0.24
.08
1.01
10
400
31.1
7
TT-20835 Welded
Stainless Steel
1/2 0.035 0.24
.08
1.14
12
550
38.5
8
TT-20849 Welded
Stainless Steel
1/2 0.049 0.24
.08
1.14
12
550
44.8
8
TT-B0435 Seamless
Stainless Steel
1/4 0.035 0.20
.08
.81
8
250
21.7
6
TT-B0635 Seamless
Stainless Steel
3/8 0.035 0.24
.08
1.01
10
400
31.1
7
TT-B0835 Seamless
Stainless Steel
1/2 0.035 0.24
.08
1.14
12
550
38.5
8
TT-B0849 Seamless
Stainless Steel
1/2 0.049 0.24
.08
1.14
12
550
44.8
8
§All values are nominal. Dimensional data to be used as reference only. *Available with .049" wall copper tubing.
**Optional insulation thicknesses are available. For other thicknesses consult factory.
Physical Data§
lbs
Steam Pressure and
Temperature
50 PSIG
@ 298°F
80 PSIG
@ 329°F
100 PSIG
@ 338°F
120 PSIG
@ 350°F
150 PSIG
@ 366°F
230 PSIG
@ 400°F
Ambient Temperature
80°F
80°F
80°F
80°F
80°F
80°F
Tube
O.D.
(in.)
Nominal
Product
O.D. (in.)
Insul.
Thick
(in.)
Heat
Loss
Jacket
temp
Heat
Loss
Jacket
temp
Heat
Loss
Jacket
temp
Heat
Loss
Jacket
temp
Heat
Loss
Jacket
temp
Heat
Loss
Jacket
temp
1/4
3/8
1/2
.81
1.015
1.14
.20
.24
.24
28.5
33.6
40.4
120
118
121
31.9
37.6
45.3
125
122
125
33.7
39.8
47.8
128
125
128
35.3
41.6
50.1
130
127
130
37.4
44.1
53.0
133
130
133
41.8
49.3
59.3
139
136
140
Q
Q
Q
Q
Q
*Heat loss is measured in Btu/Hr., per linear foot of tubing §Jacket temperature measured at the surface in °F.
NOTE: The performance fgures presented above have been calculated to be used as a guide only. Actual performance may vary
with individual plant conditions.
Performance Characteristics
Q