89
M M
M
F
G
Fax 1-888-877-5391
ThreadSize-B
Flareless
Typical Application
Pneumatic instrumentation circuits, lubricant and cooling
lines.
Working Pressure and Temperature Ranges
Up to 150 PSI from 0
o
F to + 150
o
F with thermoplastic
tubing. Up to 300 PSI from 0
o
F to + 175
o
F with soft
metal tubing.
Maximum allowable metal tube wall thickness for use
with Poly-Tite fittings:
1/8”, 3/16”
O.D. --no limitation,
1/4”
O.D.--.035 5/16”, 3/8”,1/2” O.D.--.049
Vibration
Excellent Resistance.
Temperature Range
Depends on tubing used. -65
o
F to +250
o
F
(-53
o
C to +121
o
C) with brass sleeve, -40
o
F to +150
o
F
(-40
o
C to +66
o
C) with plastic sleeve. (Refer to tubing
temperature range.)
Material
CA360 Brass body, plastic or brass sleeve.
Used With
Aluminum & copper tubing. Hard plastic tubing requires
brass sleeve. Not recommended for steel tubing.
Tolerance
+/- .02 on all dimensions. Dimension data can change
without notice. Please call us when dimensions are critical.
Advantages
No flaring of tubing required. Easy installation, captive
sleeve, pre-assembled for installation and can be reas-
sembled. Nuts rotate around the sleeve during tightening,
preventing twisting of tubing.
Assembly Instructions
1-
Cut tubing to desired length.
2-
Slide nut/sleeve assembly on tube. Threaded end
A” of nut must face toward fitting.
3-
Bottom tubing into fitting.
4-
Plastic sleeve - Tighten nut hand tight.
Brass Sleeve - Tighten nut hand tight, then an
additional 3/4 turn.
Flareless Brass Tube Fittings are Interchangeable with
Poly-Flo®, Poly-Tite® and Poly-Line® and Poly-Fit®
Tube O.D.
1/8
3/16
1/4
5/16
3/8
1/2
Thread Size-B 5/16-24
3/8-24
3/8-24
7/16-24
1/2-24
11/16-20
Built-in
Tube Support
FLARELESS
BRASS FITTINGS
B
RASS
Save 5% by ordering online at