Air Fittings
225
DPL714
877.963.4966 •
dixonvalve.com
F
Wilkerson Automatic Drain
Wilkerson Automatic Drain Valve
As liquid contaminants collect in the bowl, they raise a closed-cell cellular float. When the liquid level reaches a given point,
the float triggers a mechanism which pilots line pressure against a large area piston or diaphragm which snaps open the drain
valve. The contaminants are discharged from the drain orifice at line pressure. As the liquid level falls, the pilot valve closes, line
pressure against the piston/diaphragm returns to atmosphere and the drain valve snaps closed. A ⅛" NPT drain discharge orifice
allows the liquid discharge to be piped to a container or sewer.
with metal bowl
Automatically drains liquid water and oil from compressed air receivers and systems. Drain valve automatically opens and
closes every time the system pressure drops approximately 10 to 20 PSIG (0.7 to 1.4 bar) during the compressor cycle. An
internal piston design, which utilizes no floats, minimizes the risks associated with drain failures.
Features:
5
oz. bowl
fully automatic, float operated
full ½" NPT drain inlet
quick-disconnect clamp ring for easy bowl removal when
servicing
no electrical connections
easy installation
maximum operating conditions:
-
transparent bowl:
150
PSIG
(10.3
bar) and
32
°F
to
125
°F
(0
°C to 52°C)
-
metal bowl:
200
PSIG
(13.8
bar) and
32
°F
to
150
°F
(0
°C to 65.5°C)
Features:
for use with up to 100 HP compressors
maximum operating pressure:
200
PSIG
(13.5
bar)
temperature range:
32
°F
to
150
°F
(0
°C to 65.5°C)
minimum differential pressure required: 20 PSIG (1.4 bar)
inlet/outlet ports: ¼" NPT (F)
screen adapter: ⅜" NPT (M) inlet, ¼" NPT (M) outlet
Size
With Transparent Bowl
With Metal Bowl
Part #
Price/E
Part #
Price/E
½"
X02-04
$136.70
X02-04MB
$151.35
Size
Part #
Price/E
¼"
X51-02
$137.70
FRL's are designed for air service only, unless otherwise indicated.
Wilkerson Lockout Valves
Application:
Lockout valves are installed in pneumatic drop legs, or individual pneumatic control lines. In
accordance with OSHA procedures, lockout valves are used during maintenance and service
procedures of pneumatically (air) operated equipment.
Features:
used to comply with OSHA 29 CFR part 1910
built in port for pressure verification to meet ANSI B11 and Pmm155 requirements
inline or surface mountable
yellow cast aluminum body with red handle
pressure range:
15-300
PSI
temperature range:
40
°F
to
175
°F
(4.4
°C to 18.6°C)
Port In/Out
Port Exhaust
Part #
Price/E
½"
¾"
LV4N6D
$348.75
¾"
¾"
LV6N6D
348.75
¾"
1-¼"
LV6NAD
478.55
1"
1-¼"