93
Dixon Sanitary 2014
800.789.1718
Sample Valves
BioCheck Sampling Valves - Technical Information
Material:
•
in product contact: 1.4404/AISI316L
•
non product contact: 1.4301/AISI304
Product Contact Seals:
•
FKM bellows – PTFE
Temperatures:
•
maximum standard operating temperature: 121 °C (250 °F)
•
sterilization temperature: 135 °C (275 °F) short time*
(
approx. 20 min)
Operating pressure:
•
closing tension: max. 8 bar (116 PSI)
•
version "hand wheel": up to 16 bar
(232
PSI)
min. 6 bar
(87
PSI)
•
controlled air pressure: max.10 bar
(145
PSI)
Surfaces:
•
wetted product surfaces: R
a
<= 0.8 µm (32), optional
surfaces available
•
non product contact: R
a
=1.6 µm
Versions:
•
S = with self-closing lever
•
O = lever for open position
•
P = without lever
•
H = with hand wheel
Dimensions:
•
Pipe ø13mm x1,5mm (1 mm = 0.0394 Inch)
*
dependent on operating parameters
Technical Data
Applications:
•
The BioCheck sampling valves allow easy and safe
sampling of liquids from closed systems such as vessels and
pipelines.
Features:
•
valve body made from solid bar
•
no dead space
•
drainable
•
connections suitable for orbital welding
•
also available with only 1 port - same price -
•
hermetically sealed against environment
•
optimum cleanability
•
change of seals without special tools
•
long life of the PTFE-bellows
•
low spare part costs
•
pharmaceutical, bio-pharmaceutical, biochemical, cosmetic,
food and dairy and beverage
53-06
G