F-18
A
Pneumatics
B
Hydraulics
E
Valves
C
Thermoplastics
F
Diagnostic
D
Swivels
Appendices
Parker Hannifin Corporation
Quick Coupling Division
Minneapolis, MN
Diagnostic Products
SensoControl
®
Components and Accessories
Transducers - Analog
Pressure Transducer - Analog
Five measurement ranges: Vacuum to 8,750 PSI
Color coded for easy identification
Corrosion resistant stainless steel housing
Accuracy of 0.50% Max Full Scale
Available with PD, PDP or EMA style diagnostic couplings
Analog Transducer Part Numbers and Technical Data
PD * * -0100
PD * * -0600
PD * * -1500
PD * * -4000
PD * * -6000
Color Code
Blue
Green
Yellow
Orange
Red
Measuring Range (Pressure)
-14.5
to 220 psi
0
to 870 psi
0
to 2175 psi
0
to 5800 psi
0
to 8700
(1)
psi
Measuring Range (Temp)
-13
°F to 221°F
-13
°F to 221°F
-13
°F to 221°F
-13
°F to 221°F
-13
°F to 221°F
Max. Overload Pressure
434
psi
1450
psi
3625
psi
14500
psi
14500
psi
Output Signal (Volts)
-0.2
to 2
0
to 3
0
to 3
0
to 3
0
to 3
Response Time
1
ms
1
ms
1
ms
1
ms
1
ms
Excitation Voltage
7-12
VDC
7-12
VDC
7-12
VDC
7-12
VDC
7-12
VDC
Accuracy (max)
0.50%
FS
0.50%
FS
0.50%
FS
0.50%
FS
0.50%
FS
1.
Maximum Rated Pressure for PD Series Couplers is 6000 psi. Maximum Rated Pressure for EMA Series Couplers is 9000 psi.
2.
Analog accessories such as pressure sensors, temperature sensors, flow meters, tachometers and cables are all compatible for use with Serviceman and the Parker Service Master meters.
Materials of Construction
Transducer...........................Stainless steel
Diaphragm...........................Stainless steel
Coupler.......Chromium-6 Free Plated steel
Seal............................................Fluorocarbon
Temperature Range
Working.....................................-4° to 185°
Fluid............................................-13° to 221°
Storage.......................................-40° to 257°
Output
Accuracy (max)...................................0.50%FS
Load...............................................2m ohms
Response time.....................................<1 ms
Output signal to noise.......................0.1%FS
Resonant frequency.......................100 KHz
Voltage Requirement
7
to 12 VDC excitation voltage
Permissible ripple..............................±2% ss
Current requirement.............................5 mA
Cable End
(
Pin Out)
Pin
Mark Wire Colors
1
P
Yellow
2
T
White
3
*
Brown
4
GND
Green
5
SR**
Grey
**
in the Part Number Represents:
TA
= PD Style
PTA = PDP Style
TEMA3 = EMA3 Style (Female)
*
V
S
= 7-12 VDC
**
Sensor Recognition
2
2
0
P
S
I
1
5
b
a
r