Goodyear Rubber Products
CALL
TOLL FREE
IN THE USA
1-866-711-4673
INTERNATIONAL SALES CALL
+1-727-342-5086
WE SHIP WORLDWIDE
International Sales Click Here
Get A
Quote
Now
Home
About Us
Product Brands
Catalogs
Contact Us
Locations
Corporate Headquarters,
Clearwater, Florida, (FL)
Parker Store, Bradenton, Florida, (FL)
Parker Store, St. Petersburg, (FL)
Parker Store, Ft. Myers, Florida, (FL)
Parker Store, Naples, Florida, (FL)
Parker Store, Tampa, Florida, (FL)
<< Previous Page
Click Here
to open this page in a new window.
Next Page >>
Parker Safety Guide ! Parker Safety Guide for Selecting and Using Hose, Tubing, Fittings, and Related Accessories Parker Publication No. 4400-B.1 Revised: May 2002 WARNING: Failure or improper selection or improper use of hose, tubing, fittings, assemblies or related accessories ("Products") can cause death, personal injury and property damage. Possible consequences of failure or improper selection or improper use of these Products include but are not limited to: � Fittings thrown off at high speed. � High velocity fluid discharge. � Contact with conveyed fluids that may be hot, cold, toxic or oth- erwise injurious. � Explosion or burning of the conveyed fluid. � Sparking or explosion caused by static electricity buildup or � Electrocution from high voltage electric power lines. other sources of electricity. � Contact with suddenly moving or falling objects that are con- � Sparking or explosion while spraying paint or flammable liquids. trolled by the conveyed fluid. � Injuries resulting from inhalation, ingestion or exposure to flu- � Injections by high-pressure fluid discharge. ids. � Dangerously whipping Hose. Before selecting or using any of these Products, it is important that you read and follow the instructions below. Only Hose from Parker's Stratoflex Products Division is approved for in flight aerospace applications, and no other Hose can be used for such in flight applications. 1.0 GENERAL INSTRUCTIONS age andamount ofdeterioration ordamage orother changes,moisture 1.1 Scope: This safety guide provides instructions for selecting and usingcontent of the Hose at any particular time, and other factors. (including assembling, installing, and maintaining) these Products.The following are considerations for electrically nonconductive and For convenience, all rubber and/orthermoplastic productscommonlyconductive Hose. For other applications consult the individual catalog called "hose" or "tubing" are called "Hose" in this safety guide. Allpages and the appropriate industry or regulatory standardsfor proper assemblies made with Hose are called "Hose Assemblies". All prod-selection. ucts commonly called "fittings" or "couplings" are called "Fittings".2.1.1 ElectricallyNonconductiveHose:Certainapplicationsrequire that the All related accessories (including crimping and swaging machinesHosebe nonconductiveto preventelectricalcurrentflowor tomaintain and tooling) are called "Related Accessories". This safety guide is aelectrical isolation. For these applications that require Hose to be supplement to and is to be used with, the specific Parker publicationselectrically nonconductive, including but not limited to applications for the specific Hose, Fittings and Related Accessories that are beingnearhighvoltageelectriclines,onlyspecialnonconductive Hosecanbe considered for use. used. The manufacturer of the equipment in which the nonconductive 1.2 Fail-Safe: Hose, and Hose Assemblies and Fittings can and do failHose is to be used must be consulted to be certain that the Hose and without warning formany reasons. Design all systems and equipmentFittings that are selected areproper forthe application. Do not use any in a fail-safe mode, so that failure of the Hose or Hose Assembly orParker Hose or Fitting for any such application requiring nonconduc- Fitting will not endanger persons or property. tive Hose, including but not limited to applications near high voltage 1.3 Distribution: Provide a copy of this safety guide to each person that iselectric lines, unless (i) the application is expressly approved in the responsible for selecting or using Hose and Fitting products. Do notParker technical publication for the product, (ii) the Hose is marked select or use Parker Hose or Fittings without thoroughly reading and"nonconductive", and (iii) the manufacturer of the equipmentonwhich understanding this safety guide as well as the specific Parker publi-theHoseis tobeused specifically approvestheparticularParker Hose cations for the products considered or selected. and Fitting for such use. 1.4 User Responsibility: Due to the wide variety of operating conditions2.1.2 Electrically Conductive Hose: Parker manufacturersspecial Hose for and applications for Hose and Fittings, Parker and its distributors docertain applications that require electrically conductive Hose. not represent or warrant that any particular Hose or Fitting is suitableParker manufactures special Hose for conveying paint in airless paint for any specific end use system. This safety guide does not analyze allspraying applications. This Hose is labeled "Electrically Conductive technical parameters that must be considered in selecting a product.Airless PaintSpray Hose" onitslaylineand packaging. This Hose must The user, through its own analysis and testing, is solely responsiblebe properly connected to the appropriate Parker Fittings and properly for: grounded inorder to dissipate dangerousstatic charge buildup,which � Making the final selection of the Hose and Fitting. occurs in all airless paint spraying applications. Do not use any other � Assuring that the user'srequirementsare met and that the applica-Hose for airless paint spraying, even if electrically conductive. Use of tion presents no health or safety hazards. any other Hose or failure to properly connect the Hose can cause a � Providing all appropriate health and safety warnings on the equip-fire or an explosion resulting in death, personal injury, and property ment on which the Hose and Fittings are used. damage. � Assuring compliance with all applicable government and industryParkermanufacturesaspecialHoseforcertaincompressednaturalgas standards. ("CNG") applicationswhere staticelectricitybuildupmayoccur.Parker 1.5 Additional Questions: Call the appropriate Parker technical serviceCNG Hose assemblies comply with AGA Requirements 1-93, "HosesCoiledAirHose,Hydraulic&PTFETechnical& department if you have any questions or require any additional infor-for Natural Gas Vehicles and Fuel Dispensers". This Hose is labeled Tooling&(Fleet)TruckThermoplastic&HosePneumaticFittingsDesignApprovals&AlphanumericHose mation.Seethe Parker publication for the product beingconsidered or"ElectricallyConductive for CNGUse"onitslaylineandpackaging.This EquipmentProducts&Fit.HoseAccessoriesFittings&TubingIndexGuidesInformationAccessories used,or call 1-800-CPARKER,or go to www.parker.com, fortelephoneHose must be properly connected to the appropriate Parker Fittings numbers of the appropriate technical service department. and properly grounded in order to dissipate dangerous static charge buildup, which occurs in, for example, high velocity CNG dispensing 2.0 HOSE AND FITTING SELECTION INSTRUCTIONS or transfer. Do not use any other Hose for CNG applications where 2.1 Electrical Conductivity: Certain applications require that the Hose bestatic charge buildup may occur, even if electrically conductive. Use nonconductive to prevent electrical current flow. Other applicationsof other Hoses in CNG applications or failure to properly connect or require the Hose and the Fitting and the Hose/Fitting interface to beground this Hose can cause a fire or an explosion resulting in death, sufficientlyconductive todrain offstatic electricity. Extreme caremustpersonal injury, and property damage. Care must also be taken to be exercised when selecting Hose and Fittings for these or any otherprotect against CNG permeation through the Hose wall. See section applications in which electrical conductivity or nonconductivity is a2.6, Permeation, for more information. Parker CNG Hose is intended factor. for dispenser and vehicle use at a maximum temperature of 180�F. The electrical conductivity or nonconductivity of Hose and Fittings isParkerCNGHoseshouldnotbeusedinconfinedspacesorunventilated dependent upon manyfactorsandmay besusceptibletochange. These areas or areas exceeding 180�F. Final assemblies must be tested for factors include but are not limited to the various materials used toleaks. CNG Hose Assemblies should be tested on a monthly basis for make the HoseandtheFittings,Fitting finish(someFitting finishesareconductivity per AGA 1-93. electricallyconductivewhileothersare nonconductive),manufacturingParkermanufacturersspecialHoseforaerospace inflightapplications. methods(includingmoisturecontrol),how theFittingscontacttheHose,Aerospace in flight applications employing Hose to transmit fuel, 299 Parker Hannifin Corporation Parflex Division Ravenna, Ohio
Goodyear Rubber Products