Page 42 - GarlockFluidSealing2010

SEO Version

B-10
Styles 214 and 215
Temperature
214 Pressure
215 Pressure
psi
bar
psi
bar
50°F
10°C
178
12
132
9
100°F
50°C
165
11
120
8
150°F
65°C
150
10
103
7
200°F
90°C
130
9
90
6
250°F
120°C
110
8
75
5
300°F
150°C
92
6
60
4
350°F
180°C
78
5
50
3.5
400°F
205°C
65
4.5
42
3
450°F
230°C
60
4
35
2
Pressure and Vacuum Rating
Garlock PTFE expansion joints and couplings have
pressure ratings high enough to handle most applica-
tions. As the pipe size gets larger, Garlock increases
the bellows thickness and the strength of the reinforc-
ing rings to compensate for the change in internal
forces. This permits the same high pressure rating for
all sizes.
These PTFE concentric spool-type fexible cou-
plings are designed to reduce noise and compensate
for expansion, contraction and minor piping misalign-
ment in chemical processing, air conditioning and
heating systems.
Style 214
¦
Two convolutions
¦
Temperature: -100°F (-70°C) to +450°F (+230°C)
Pressure:
To 178 psig (12 bar),
Full vacuum to +350°F (+180°C)
Style 215
¦
Three convolutions
¦
Temperature: -100°F (-70°C) to +450°F (+230°C)
Pressure:
To 132 psig (9 bar),
Full vacuum to +180°F (+80°C)
Benefts
¦
Convolution shape provides extra-long fex life at
high temperatures
¦
Proprietary contour molding process ensures con-
sistent wall thickness for blowout resistance
¦
PTFE body withstands corrosion, water, steam, and
most chemicals and gases
¦
Higher pressure and temperature ratings mean
extended service life in most piping systems
¦
Preset restriction bolts prevent over-extension
¦
Available silicone-free
Design
¦
Complete assembly includes fuorocarbon resin
PTFE body, plated ductile iron fanges, polyethyl-
ene-covered restriction bolts and corrosion-resis-
tant reinforcing rings
¦
Standard sizes from 1" (25 mm) through 8" (200
mm) pipe l.D.
WARNING:
Properties/applications shown throughout this brochure are typical. Your specifc applica-
tion should not be undertaken without independent study and evaluation for suitability.
For specifc application recommendations consult Garlock. Failure to select the proper
sealing products could result in property damage and/or serious personal injury.
Performance data published in this brochure has been developed from feld testing,
customer feld reports and/or in-house testing.
While the utmost care has been used in compiling this brochure, we assume no respon-
sibility for errors. Specifcations subject to change without notice. This edition cancels
all previous issues. Subject to change without notice.
GARLOCK is a registered trademark for packings, seals, gaskets, and other products
of Garlock.